Sources and materials for flex/derivatives paper. All author-originated items here are released under the following licences: * text and images: CC-BY-4.0 * data: CC0 * code: Apache 2.0 and CC-BY-4.0 Pint of Science 2026 public talk: * https://www.earth.org.uk/img/meet/2026-Pint-of-Science/20260518-PintOfScience.pdf Late LaTeX proofs of the manuscript: * proof.tex Published PDF (DOI 10.20935/AcadEnergy8514): * Grid_flex_rhymes_with_derivatives_tradin.pdf GB grid carbon intensity gCO2e/kWh and demand GW 24h snapshot from 2026-05-11: * 20260511-GB-Grid-Intensity.png Profile derived from Elexon GB grid data for Profile Class 1 - Domestic Unrestricted Customers average winter weekday: * class-1-winter-weekday-Elexon-load-profile.png * class-1-winter-weekday-Elexon-load-profile.csv (startUTC, nSamples, Wdemand) Note that this is not data originated by the author. Comparative net grid load for 16WW for sample months in each quarter of 2025, source 16WW Enphase battery system, weekdays only versus Elexon class 1 domestic winter weekday reference: * quarters-2025-refc1.weekday.pdf (startUTC, Wnet; class 1 vs 4Q 16WW) * 16WW-load-profile-quarters-2025-weekday.202503.csv (startUTC, n, Wgross, Wnet) * 16WW-load-profile-quarters-2025-weekday.202506.csv (") * 16WW-load-profile-quarters-2025-weekday.202509.csv (") * 16WW-load-profile-quarters-2025-weekday.202512.csv (",SDgross,SDnet) And for all days, ie including weekends: * 16WW-quarters-2025-refc1.pdf (startUTC, Wnet; class 1 vs 4Q 16WW) * 16WW-load-profile-quarters-2025-all.202503.csv (startUTC, n, Wgross, Wnet) * 16WW-load-profile-quarters-2025-all.202506.csv (") * 16WW-load-profile-quarters-2025-all.202509.csv (") * 16WW-load-profile-quarters-2025-all.202512.csv (",SDgross,SDnet) CSV second column (n) is the (day) sample count. Enphase monthly 15-minute cadence dataset for further analysis, GZIPped: * net_energy_202512.csv.gz 16WW house front view: * 16WW-front-20260607.jpg 16WW overall utility energy carbon footprint as of 2025: * 16WWYearlyEnergyCarbonFootprint.pdf * 16WWYearlyEnergyCarbonFootprint.dat 16WW per-day kWh of eheat/variables h1d,h1b,imp,exp,h2d,h2b,hph4 for 2026-05: * 202605-eheatDailyRecentDetailed.pdf * 202605.daily.csv (eddi daily flows by above variables) * 202512.daily.csv (comparison daily data for mid-winter) CSV second column (n) is the (hour) sample count. 16WW per-hour-of-day battery electric heat W for 2026-05: * bucketed.eddi-eheat.202605.all.pdf * bucketed.eddi-eheat.202605.all.csv CSV second column (n) is the (day) sample count. The two final columns are the standard deviation of the previous two. 16WW per-hour-of-day battery charge and discharge W for 2026-05: * bucketed.enphase-batt.202605.all.pdf * bucketed.enphase-batt.202605.all.csv CSV second column (n) is the (day) sample count. The two final columns are the standard deviation of the previous two. 16WW immersion heat W for 2026-06: * bucketed.eddi-iheat.202506.all.csv CSV second column (n) is the (day) sample count. The two final columns are the standard deviation of the previous two. 16WW 2-day per-minute grid-tied PV generation W ending 2026-06-09 (from the SunnyBoy inverters, aggregated via a SunnyBeam receiver): * 20260609-gridTiePower.pdf * 20260609-gridTiePower.csv (datetimeUTC, W) 16WW heat-pump control schedules as of 2026-06: * 16WW-heat-pump-control.png Snapshot of the per-minute myenergi Eddi diverter-management script run on a Raspbery Pi to provide dynamic grid response: * 20260816-eddiFreqResponse-netrc.sh