WEBVTT


NOTE Transcript 2024-05-24 from MP3 by https://elvery.net/prototypes/transcribe/ on my MacBook Air M1 on maximum quality setting.
NOTE Body significantly edited.


00:00.000 --> 00:08.560
Okay, good morning everybody, thank you for coming along. I want to try and inspire you to go solar,


00:08.560 --> 00:17.120
but equally give you a few lessons and what to watch out for, especially on sales tactics and


00:17.120 --> 00:27.680
what lessons I've learned. So basically we've got two technologies, one is based around thermal


00:27.680 --> 00:35.360
for water, or photovoltaic generating electricity. Slightly different technologies, we're definitely


00:35.360 --> 00:44.640
going down the photovoltaic route. So benefits of it, meeting your electrical needs for quite a bit


00:44.640 --> 00:51.920
of the year and a little bit for other parts. Storage of power and a battery, so if you go


00:51.920 --> 00:59.360
for electric vehicle ... for example, or just generally meeting your overnight demands for


00:59.360 --> 01:10.320
electricity most of the year. Then otherwise excess energy gets fed into the grid and you can even,


01:10.320 --> 01:17.280
depending on the power you're generating etc, use it for immersion heaters and so on.


01:20.640 --> 01:28.800
First thing to consider is the quality of your roof - it needs to be in fairly good


01:28.800 --> 01:40.080
nick, not going to struggle under the weight of panels. And you may have 8, you may have 12,


01:40.080 --> 01:46.800
you may have 16 panels. But hopefully, whoever you choose to come and do the installation will very quickly identify if there are any things to be concerned about.  Optimum pitch (the angle of of the roof) 36 degrees - but don't let that put you off at all.  Direction of the roof facing optimum is south again but


02:08.160 --> 02:15.680
it will produce almost any direction it's facing. Going back to the pitch, if you have to use a flat


02:15.680 --> 02:24.640
roof for all, you can do. One thing is that a lot of installations are done with panels in


02:24.640 --> 02:33.120
series and so you may have (say) seven panels on a string. If a shadow gets onto one of those


02:33.120 --> 02:43.280
panels it's the weakest link in principle that applies. There are ways round that don't worry. So this is to


02:43.280 --> 02:53.840
give you a quick idea of what your panel productivity may be reduced by based on the


02:53.840 --> 03:03.200
direction and tilt etc. My roof is actually west facing so I get about four fifths of what I might get if it were due south.


03:03.200 --> 03:10.640
Somethings you can do something about it, others you can't. But don't let that deter


03:10.640 --> 03:21.680
is the reason I've put that on. As I mentioned, shadows are something to be wary of, but if predominantly


03:21.680 --> 03:33.200
you have none during the 10 'til 4, you've really nothing to greatly worry about. Technology can actually


03:33.200 --> 03:41.760
get around as a problem. You can have what are called panel level optimisers. So basically that's


03:43.040 --> 03:52.400
super duper technology which up at the panel level optimises and then sends the direct current down to your


03:52.400 --> 04:01.440
inverter device. An inverter device is a fairly chunky piece of metal that you will have typically in a


04:01.440 --> 04:09.440
garage, that you might have elsewhere; what I don't recommend is the roof. Microinverters:


04:09.440 --> 04:15.840
a little bit more sophisticated because they don't actually have, you don't need to have the


04:15.840 --> 04:23.760
inverter in the garage or elsewhere. The inversion to AC is actually done at the panel level and


04:23.760 --> 04:31.120
there's further technology; smart panels but that's going well beyond what any of us would need.


04:31.120 --> 04:38.560
Good news on the weight side, just in case you do have any qualms on that. There is


04:38.960 --> 04:47.440
a lightweight panel coming now through the Dutch firm that invented them, that is also made of


04:47.440 --> 04:55.280
recycled material. They are introducing something for commercial installations already,


04:55.280 --> 05:04.320
and a residential premise installation is planned for next year. But only if you need to worry about


05:04.880 --> 05:12.320
the weight of your panels would that be of any interest. So you'll find the last two


05:12.320 --> 05:20.080
slides here that there are a raft of Web sites. They are brilliant for going and doing your own


05:20.080 --> 05:26.720
homework.  Read through it at your own pace rather than trying to absorb it all from people like me,


05:26.720 --> 05:33.760
or especially salesmen trying to push things. First things first, check if you're


05:33.760 --> 05:39.920
likely to need any planning permission, but generally speaking that's unlikely to get in the


05:39.920 --> 05:48.560
way. If there are any people who happen to be on Universal Credit or Pension Credit, there are


05:48.560 --> 05:59.600
significant grants available under what's called ECO4. Otherwise though [you'll] be struggling to get any


05:59.600 --> 06:08.480
grant support for it. Another very important thing is the installation. Make sure that you're


06:08.480 --> 06:17.920
using a Microgeneration Certification Scheme accredited installer. I mean deep difficulty


06:17.920 --> 06:26.000
trying to get any of the benefits you can get if you haven't got an accredited installer. Another lesson:


06:26.720 --> 06:33.440
do due diligence - word of mouth - do a bit of research [of] the installers you choose.


06:33.440 --> 06:43.520
And while some Web sites say three quotes I would recommend five. If you have a good idea


06:43.520 --> 06:49.360
and you perhaps don't necessarily go for the cheapest one, the next one you have to judge


06:49.920 --> 07:00.160
the quality of the individuals that come along. A pleasant surprise for me. I had mine


07:00.160 --> 07:10.000
installed in 2010, and I thought four percent decrease per annum productivity of the


07:10.000 --> 07:18.880
panels. It is nothing like as severe as that. You may find that between a quarter of a percent and one


07:18.880 --> 07:29.200
percent with a certain type would be the decreasing productivity, to quash that. And duration... lovely


07:29.200 --> 07:39.440
story. It's the AMSAT-OSCAR 7. That lost communication in 1981, about seven years after;


07:39.440 --> 07:47.520
corrosion, went open the circuit in 2002, suddenly communicating again. And here you are,


07:47.520 --> 07:55.200
2023 it is still functioning. IE the best part of 50 years getting panels still working.


07:55.200 --> 08:02.640
What is it? Is it some space thing? Yes, low orbit satellite. But there are plenty of stories


08:02.640 --> 08:08.240
of people who have got PV which has been working 40 years after it has gone up, so it's not


08:08.240 --> 08:15.440
out on a limb. No, that sort of message is - it is probably not likely we are going to


08:16.320 --> 08:27.040
get into issues, and productivity is pretty good. So typically say the inverter would


08:27.040 --> 08:34.960
be housed in the garage as I mentioned, or a utility room, and not the loft. But the reliability of the inverter - I was very much warned [that] after 6 or 7 years I would need to get a replacement, but that's not the general experience now. And many come with a decade plus or even a 25 year 


08:49.600 --> 08:59.360
guarantee with some of them I believe. ... . Something you are generally


08:59.360 --> 09:07.360
not warned about are pigeons, and they can be a real nuisance. Certainly, once they find they can


09:08.400 --> 09:17.120
get under and nest there you will be bothered by them. And a couple of images on the top as to what they can


09:17.120 --> 09:31.120
do to your panels over time. Common remedies for this. Make sure you install some very robust sturdy


09:31.120 --> 09:39.680
wire. I've just had to have mine replaced and the firm that did it has given me a 15 year guarantee and I trust them.


09:39.680 --> 09:50.400
Make sure it's sturdy stuff. Spikes: most Web sites say to put spikes, and spikes work.  They don't!


09:50.400 --> 09:58.720
At least two people in the profession I have spoken with, say it's common knowledge and


09:58.720 --> 10:04.000
there's a lot of people in the trade. You will find hundreds of sites that say they do.


10:04.000 --> 10:11.520
Under that "the customer is often confused as to why the spikes they've paid someone else to put


10:11.520 --> 10:16.880
on the roof didn't keep the pigeons away. The answer is actually pretty simple. Those bird


10:16.880 --> 10:23.360
spike strips don't move and they can't cover the entire roof. Therefore it just didn't work."


10:24.000 --> 10:33.600
So like I said, get some sturdy wire. The other thing, early sales tactics,


10:33.600 --> 10:42.240
nice lovely rectangles if it's all level and you benefit all year: you don't. One day in summer


10:42.240 --> 10:46.400
you'll produce as much panelling as you would in about two months.


10:48.000 --> 10:56.080
So I said to people eight / nine months of the year you will find that you'll generally get


10:56.080 --> 11:02.560
self-sufficiency of the amount of energy you produce from your panels but not 12 months of the year.


11:02.560 --> 11:16.880
And to give you an example right, the top one is based on about 12 years of metrics. The bottom


11:16.880 --> 11:31.600
one which is a direct south facing is about five years. Obviously it's a sizeable investment to be


11:31.600 --> 11:40.720
interested in what you can do to recover the the outlay. And savings on energy bills obviously


11:40.720 --> 11:48.880
fluctuate according to prices, and that can and your usage profile, so you can save anything from


11:48.880 --> 11:53.440
£160 to £350 a year.


12:02.880 --> 12:12.400
Well the utilisation of the panels and what they produce is generally 20 - 25 percent.


12:12.400 --> 12:18.080
The savings depend on the size of the panels and the productivity you get.


12:18.080 --> 12:26.640
The other thing is what's called the Smart Export Guarantee.


12:26.640 --> 12:35.520
Years gone by we had what was called Feed-in tariff. That was a perk / rebate from the government to


12:35.520 --> 12:43.680
encourage people to have it. Now you have to export your excess electricity and you can get


12:43.680 --> 12:52.800
prices. Now the Smart Export Guarantee rates vary greatly. You might get a penny a unit up to


12:52.800 --> 13:00.800
as high as 40 pence. So you need to do a bit of research and find that who're offering schemes


13:00.800 --> 13:11.280
and watch out for some of the terms and conditions often. But if things move to a more Time-of-Use


13:11.280 --> 13:17.920
for charging for electricity, obviously you're likely to gain significantly. So your panels


13:17.920 --> 13:25.200
are producing in the afternoon around the peak time for fair bits of the year. Obviously winter


13:25.200 --> 13:35.920
doesn't make a great deal of energy. The next one, the root point is regarding the


13:35.920 --> 13:45.440
Energy Performance Certificate. Your score will go up for sure, but here we are I think they


13:45.440 --> 13:53.760
created in about 2007. Say four years ago some articles in the paper explaining the government


13:53.760 --> 14:02.800
because metrics and measurements parameters haven't been changed in 15 years. So you had examples


14:02.800 --> 14:11.680
where responsible people were put in batteries and then the score have actually decreased and


14:11.680 --> 14:18.080
heat pumps as well, especially with the high usage of electricity by the heat pumps, there


14:18.080 --> 14:29.920
were some perverse impacts. Lord Deben is still trying to get something satisfactory. So be warned.


14:29.920 --> 14:40.000
I emphasize the MAY increase property value, because if you've got (say) something from the


14:40.000 --> 14:47.360
feed-in tariff and generating a lot of income stream each year that will definitely be a big


14:47.360 --> 14:54.080
appeal and the feed-in tariff is transferable. Smart export isn't, what you can obviously do


14:54.080 --> 14:59.920
it for the next person who can use it and gain it, but you're not quite getting the


15:00.000 --> 15:04.000
guaranteed regular income stream that feed-in tariff gave.


15:04.000 --> 15:17.000
So that's why I said "MAY", you may get 15-20% of what we put on the balance, you may get 50% for demand in the market.


15:17.000 --> 15:28.000
Basically in terms of optimising it, try to adjust your usage patterns in terms of recharging things during the day.


15:28.000 --> 15:38.000
I mentioned immersion heat, so you may want to put that on in the early afternoon when the system is producing heavily.


15:38.000 --> 15:48.000
So a few conditions, as I mentioned, Smart Export Guarantee, you must have the Microgeneration Certification Scheme qualification.


15:48.000 --> 16:00.000
And that also necessitates a smart meter. There are various issues with that technology, and rolling that out, as we know.


16:00.000 --> 16:08.000
As I mentioned with the Energy Performance Certificates, net zero targets for Energy Performance Certificates...


16:08.000 --> 16:16.000
Quite where we're going to head with that in five, ten years' time is difficult to see.


16:16.000 --> 16:28.000
Another thing is it could potentially even affect mortgage rates, maybe incentives going: all sorts of possibilities.


16:28.000 --> 16:39.000
So, indirect benefits: the government has cut VAT on products.


16:39.000 --> 16:51.000
I assure you that a mid-life upgrade of a battery, until recently, ..., you paid 20% VAT on the battery.


16:51.000 --> 16:55.000
That happened to me, but thankfully it has been removed.


16:55.000 --> 17:03.000
Panelling, insulation, all these sorts of things have now been zero VATted, so that's a good incentive.


17:03.000 --> 17:10.000
Obviously from a responsibility perspective, reducing your carbon footprint,


17:10.000 --> 17:29.000
there's some various numbers in terms of the reduced emissions, and generally per kilowatt of your system, you'll get back 900 kilowatt hours per annum.


17:29.000 --> 17:36.000
The thing with panels, of course, they're getting better as the years go by.


17:36.000 --> 17:39.000
For instance [when] my system was installed,


17:39.000 --> 17:50.000
each panel was 285 watts. You will now get the normal 360, around 400 plus watt panels that are available.


17:50.000 --> 17:58.000
The other nice thing is to always consider local employment, depending on who you've select.


17:58.000 --> 18:09.000
The last two slides are some Web sites where you can go and do your own research.


18:09.000 --> 18:19.000
Some very good quality ones. Federation of Master Builders, comprehensive step by step, all the things you need to do.


18:19.000 --> 18:30.000
Centre for Sustainability, sustainable energy, not just solar batteries. There are lots and lots of ideas to make your place greener.


18:30.000 --> 18:35.000
Friends of the Earth, saving on [...]


18:35.000 --> 18:42.000
Here you go. Something about the microinverters and optimisation configurations.


18:42.000 --> 18:49.000
Just to help you with the DC/AC aspects I mentioned earlier, and cost-effectiveness.


18:49.000 --> 18:57.000
It's a bit of a misleading end of that Web site address "free" solar panels!


18:57.000 --> 19:17.000
What I would say is that, don't take up any of these offers where they will install and offer you, bait you with, free electricity: there are pitfalls with that as [folks] in Stoke on Trent and elsewhere have found.


19:17.000 --> 19:29.000
I emphasise the diligence because of the firm Green Energy Together, rather recommended by government,


19:29.000 --> 19:38.000
and they went bust last year, and folded, so you have to do your due diligence.