@article{neubert2022multifamily,
title={Analysis of the Operation Characteristics of a Hybrid Heat Pump in an Existing Multifamily House Based on Field Test Data and Simulation},
author={Daniel Neubert and Christian Gl{\"u}ck and Julian Schnitzius and Armin Marko and Jeannette Wapler and Constanze Bongs and Clemens Felsmann},
doi={10.3390/en15155611},
url={https://doi.org/10.3390%2Fen15155611},
urldate={2023-10-31},
year=2022,
month={08},
publisher={{MDPI} {AG}},
volume={15},
number={15},
pages={5611},
journal={Energies},
annote={Quote: "The thermostatic radiator valves control the operative temperature onto the user set point Ttrv,set for each zone..."  Quote: "Due to the unrenovated state of the building, a weather compensation control (WCC) with 76{\degree}C flow temperature at -15{\degree}C outdoor temperature was applied..."},
}