@techreport{becker2023AWHP,
title={Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage},
author={Becker, Stephen and Hoeschele, Marc and German, Alea},
institution={Office of Energy Efficiency and Renewable Energy, US Department of Energy},
url={https://www.osti.gov/biblio/1984584},
urldate={2025-01-10},
DOI={10.2172/1984584},
howpublished={\url{https://www.osti.gov/servlets/purl/1984584}},
year={2023},
month={05},
number={DOE/GO-102023-5871},
address={Oak Ridge, Tennessee 37831-0062, US},
abstract={This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction.},
annote={Uses EnergyPlus version 9.6.  The AWHP system was modeled using the AWHP objects HeatPump:PlantLoop:EIR:Cooling and HeatPump:PlantLoop:EIR:Heating.  Quote: "The part load modeling is a critical piece in trying to accurately represent the variable-speed performance of the AWHP system. This remains the biggest challenge working within the EnergyPlus framework for this system type."},
}